In accordance with DIN ISO 10656 and VW-Audi construction standards
BV 39-V-3037 and BV 39-V-5711, the transformer types listed below
are currently in use:
INTEGRATED AND MACHINE TRANSFORMERS
Connection Layout: A
|

|
 |
|
- Temperature monitoring
- Measuring coil (for CCR) standard
|
| TYPE |
NOMINAL OUTPUT
S50
(at 50% ED) |
SECONDARY CONTINUOUS CURRENT
I2p |
SECONDARY VOLTAGE
U20 |
WEIGHT |
DIMENSIONS
w x h xd |
SECONDARY SIDE TRANSFORMER
IMPEDANCE
Z = R + jXL
(400 V version) |
| |
[ kVA ] |
[ kA ] |
[ V ] |
[ kg ] |
[ mm ] |
[ µW
] |
4-V-62-TM
A1-7,1-85-400-TM |
85 |
8.5 |
7.1 |
83 |
ca. 184 x 235 x 460 |
82 = 65 + j 50 |
4-V-70-TM
A1-12,5-160-400-TM |
160 |
9.0 |
12.5 |
119 |
ca. 184 x 235 x 615 |
115 = 90 + j 71 |
4-V-64-TM
G2-13,4-340-400-TM |
340 |
17.9 |
9.5 / 13.4 |
260 |
ca. 250 x 360 x 630 |
88 = 59 + j 65 |
4-V-61-TM
G2-16,6-530-400-TM |
530 |
22.5 |
8.3 / 10.5
13.3 / 16.6 |
371 |
ca. 280 x 400 x 810 |
51 = 37 + j 35 |
SPLIT-CORE TYPE TRANSFORMERS
Connection Layout: J
|

|
 |
|
- Temperature monitoring
- Measuring coil (for CCR)
|
| TYPE |
NOMINAL OUTPUT
S50
(at 50% ED) |
SECONDARY CONTINUOUS CURRENT
I2p |
SECONDARY VOLTAGE
U20 |
WEIGHT |
DIMENSIONS
w x h xd |
SECONDARY SIDE TRANSFORMER
IMPEDANCE
Z = R + jXL
(400 V version) |
| |
[ kVA ] |
[ kA ] |
[ V ] |
[ kg ] |
[ mm ] |
[ µW ]
|
| J - 7,1 - 5,4 - 400 - TM |
54 |
5.4 |
7.1 |
28.8 |
ca. 125 x 160 x 292 |
138 = 121 + j 66 |
| J - 10,0 - 5,4 - 400 - TM |
76 |
5.4 |
10.0 |
38.5 |
ca. 125 x 160 x 360 |
166 = 150 + j 71 |
|