TRANSFORMERS

VW / AUDI STANDARD

In accordance with DIN ISO 10656 and VW-Audi construction standards BV 39-V-3037 and BV 39-V-5711, the transformer types listed below are currently in use:

INTEGRATED AND MACHINE TRANSFORMERS


Connection Layout: A

 
  • Temperature monitoring
  • Measuring coil (for CCR) standard

TYPE NOMINAL OUTPUT
S50
(at 50% ED)
SECONDARY CONTINUOUS CURRENT
I2p
SECONDARY VOLTAGE
U20
WEIGHT DIMENSIONS
w x h xd
SECONDARY SIDE TRANSFORMER IMPEDANCE
Z = R + jXL
(400 V version)
  [ kVA ] [ kA ] [ V ] [ kg ] [ mm ] [ µW ]
4-V-62-TM
A1-7,1-85-400-TM
85 8.5 7.1 83 ca. 184 x 235 x 460  82 = 65 + j 50
4-V-70-TM
A1-12,5-160-400-TM
160 9.0 12.5 119 ca. 184 x 235 x 615 115 = 90 + j 71 
4-V-64-TM
G2-13,4-340-400-TM
340 17.9 9.5 / 13.4 260 ca. 250 x 360 x 630 88 = 59 + j 65
4-V-61-TM
G2-16,6-530-400-TM
530 22.5 8.3 / 10.5
13.3 / 16.6
371 ca. 280 x 400 x 810 51 = 37 + j 35


SPLIT-CORE TYPE TRANSFORMERS


Connection Layout: J

 
  • Temperature monitoring
  • Measuring coil (for CCR)

TYPE NOMINAL OUTPUT
S50
(at 50% ED)
SECONDARY CONTINUOUS CURRENT
I2p
SECONDARY VOLTAGE
U20
WEIGHT DIMENSIONS
w x h xd
SECONDARY SIDE TRANSFORMER IMPEDANCE
Z = R + jXL
(400 V version)
  [ kVA ] [ kA ] [ V ] [ kg ] [ mm ] [ µW ]
J - 7,1 - 5,4 - 400 - TM 54 5.4 7.1 28.8 ca. 125 x 160 x 292 138 = 121 + j 66
J - 10,0 - 5,4 - 400 - TM 76 5.4 10.0 38.5 ca. 125 x 160 x 360 166 = 150 + j 71