TRANSFORMERS

SUSPENDED TRANSFORMERS

Application
Integration in manual spot and suspended compact units, alson in the Centroidal axis of robots
Characteristics Compact, fully-cast design
Water-cooled secondary circuit
Standards DIN 44766, EXPERT standard, BMW, Mercedes Benz 15.19.042, Opel, Ford UWT 002, NF A82-042

Connection Layout: C
Output Range: 100 - 200 kVA
Secondary Voltages: 12.5 - 25.0V (single and multi-stage versions)
Other Features (depending upon standard):
  • Temperature monitoring
  • Measuring coil (for CCR)

NOMINAL OUTPUT
S50
(at 50% ED)
SECONDARY CONTINUOUS CURRENT
I2p
SECONDARY VOLTAGE
U20
WEIGHT DIMENSIONS
w x h xd
SECONDARY SIDE TRANSFORMER IMPEDANCE
Z = R + jXL
(400 V version)
[ kVA ] [ kA ] [ V ] [ kg ] [ mm ] [ µW ]
100 3.9 18.0 109 ca. 184 x 235 x 540
184 = 156 + j 98
100
3.9
12.5 / 18.5 140 ca. 230 x 302 x 555 145 = 117 + j 85 
115
4.5
17.9
116 ca. 200 x 275 x 509 164 = 136 + j 92  
150
4.6
22.8
132 ca. 200 x 275 x 544 200 = 176 + j 95  
150
5.3
20.0
121 ca. 184 x 235 x 607 163 = 139 + j 85  
160
4.5
25.0
163 ca. 197 x 260 x 645
200 = 170 + j 105  
200
6.4
15.3 / 22.3
179 ca. 230 x 302 x 640 151 = 125 + j 84


Connection Layout: D
Output Range: 100 - 180 kVA
Secondary Voltages: 18.0 - 25.2V (single and multi-stage versions)
Other Features (depending upon standard):
  • Temperature monitoring
  • Measuring coil (for CCR)
  • Adapter for coaxial cable

NOMINAL OUTPUT
S50
(at 50% ED)
SECONDARY CONTINUOUS CURRENT
I2p
SECONDARY VOLTAGE
U20
WEIGHT DIMENSIONS
w x h xd
SECONDARY SIDE TRANSFORMER IMPEDANCE
Z = R + jXL
(400 V version)
[ kVA ] [ kA ] [ V ] [ kg ] [ mm ] [ µW ]
100 3.9 18,0 109 ca. 184 x 235 x 520 253 = 190 + j 167
125 4.0 22,0 127 ca. 184 x 235 x 580 229 = 183 + j 138
150 4.8 22,0 127 ca. 184 x 235 x 570 196 =147 + j 130 
180 5.0 18.0 / 20.0
22.4 / 25.2
127 ca. 184 x 235 x 590 225 = 180 + j 135