TRANSFORMERS

SPLIT CORE TYPE TRANSFORMERS

 

Connection Layout: H
Output Range: 32 - 36 kVA
Secondary Voltages: 5.6 - 6.3 V (single stage version)

NOMINAL OUTPUT
S50
(at 50% ED)
SECONDARY CONTINUOUS CURRENT
I2p
SECONDARY VOLTAGE
U20
WEIGHT DIMENSIONS
w x h xd
SECONDARY SIDE TRANSFORMER IMPEDANCE
Z = R + jXL
(400 V version)
[ kVA ] [ kA ] [ V ] [ kg ] [ mm ] [ µW ]
32 4.0 5.6 19.0 ca. 106 x 150 x 250  147 = 134 + j 60
36 4.0 6.3 21.0 ca. 106 x 150 x 270 155 = 124 + j 93 


Connection Layout: J
Output Range: 48 - 103 kVA
Secondary Voltages: 6.3 - 13.5 V (multi-stage versions)

NOMINAL OUTPUT
S50
(at 50% ED)
SECONDARY CONTINUOUS CURRENT
I2p
SECONDARY VOLTAGE
U20
WEIGHT DIMENSIONS
w x h xd
SECONDARY SIDE TRANSFORMER IMPEDANCE
Z = R + jXL
(400 V version)
[ kVA ] [ kA ] [ V ] [ kg ] [ mm ] [ µW ]
48 5.4 6.3 26.5 ca. 125 x 160 x 269 127 = 111 + j 61 
54 5.4 7.1 28.8 ca. 125 x 160 x 292 138 = 121 + j 66 
61 5.4 8.0 32.0 ca. 125 x 160 x 309 147 = 138 + j 51
76 5.4 10.0 38.5 ca. 125 x 160 x 360 166 = 150 + j 71
103 5.4 13.5 51.5 ca. 125 x 160 x 460 208 = 187 + j 91