INTRODUCTION
STANDARD TURNTABLES
TRUNNION DRIVES
LARGE TURNTABLES
GLOBOIDAL DRIVES
GLOBOIDAL ROTARY TABLE DRIVES
PARALLEL SHAFT INDEX DRIVES
INTRODUCTION
INTEGRATED TRANFORMERS
MEDIUM FREQUENCY TRANFORMERS
SUSPENDED TRANSFORMERS
MACHINE TRANSFORMERS
SPLIT-CORE TYPE TRANSFORMERS
TRANSFORMERS FOR HEATING APPLICATIONS
CURRENT-GUIDED ADJUSTABLE TRANSFORMERS
BMW STANDARD
DAIMLER-CHRYSLER STANDARD
OPEL STANDARD
VW/AUDI STANDARD
SPLIT CORE TYPE TRANSFORMERS
You are reading:
Transformers
: Split Core
Connection Layout: H
Output Range:
32 - 36 kVA
Secondary Voltages:
5.6 - 6.3 V (single stage version)
NOMINAL OUTPUT
S
50
(at 50% ED)
SECONDARY CONTINUOUS CURRENT
I
2p
SECONDARY VOLTAGE
U
20
WEIGHT
DIMENSIONS
w x h xd
SECONDARY SIDE TRANSFORMER IMPEDANCE
Z = R + jX
L
(400 V version)
[ kVA ]
[ kA ]
[ V ]
[ kg ]
[ mm ]
[ µ
W
]
32
4.0
5.6
19.0
ca. 106 x 150 x 250
147 = 134 + j 60
36
4.0
6.3
21.0
ca. 106 x 150 x 270
155 = 124 + j 93
Connection Layout: J
Output Range:
48 - 103 kVA
Secondary Voltages:
6.3 - 13.5 V (multi-stage versions)
NOMINAL OUTPUT
S
50
(at 50% ED)
SECONDARY CONTINUOUS CURRENT
I
2p
SECONDARY VOLTAGE
U
20
WEIGHT
DIMENSIONS
w x h xd
SECONDARY SIDE TRANSFORMER IMPEDANCE
Z = R + jX
L
(400 V version)
[ kVA ]
[ kA ]
[ V ]
[ kg ]
[ mm ]
[ µ
W
]
48
5.4
6.3
26.5
ca. 125 x 160 x 269
127 = 111 + j 61
54
5.4
7.1
28.8
ca. 125 x 160 x 292
138 = 121 + j 66
61
5.4
8.0
32.0
ca. 125 x 160 x 309
147 = 138 + j 51
76
5.4
10.0
38.5
ca. 125 x 160 x 360
166 = 150 + j 71
103
5.4
13.5
51.5
ca. 125 x 160 x 460
208 = 187 + j 91