In accordance with DIN ISO 10656, and Opel standards, the transformer
types (with varying primary voltages U1)listed below
are currently in use:
INTEGRATED TRANSFORMERS
Connection Layout: B2
|
Connection Layout: B
|
 |
 |
- Temperature monitoring
- Measuring coil (for CCR)
- Secondary circuit monitoring standard
|
| TYPE |
NOMINAL OUTPUT
S50
(at 50% ED) |
SECONDARY CONTINUOUS CURRENT
I2p |
SECONDARY VOLTAGE
U20 |
WEIGHT |
DIMENSIONS
w x h xd |
SECONDARY SIDE TRANSFORMER
IMPEDANCE
Z = R + jXL
(400 V version) |
| |
[ kVA ] |
[ kA ] |
[ V ] |
[ kg ] |
[ mm ] |
[ µW
] |
| B/2 - 4 - 10,0 - 50 - U1 - TMS |
50 |
3.5 |
7.1 / 8.0
9.0 / 10.0 |
73 |
ca. 92 x 235 x 710 |
130 = 120 + j 51 |
| B6-(1...5)-10,0-100-U1-TMS |
100 |
7.1 |
7.1 / 8.0
9.0 / 10.0 |
115 |
ca. 184 x 235 x 560 |
67 = 51 + j 44 |
SUSPENDED TRANSFORMERS
Connection Layout: C
|

|
 |
|
| |
| TYPE |
NOMINAL OUTPUT
S50
(at 50% ED) |
SECONDARY CONTINUOUS CURRENT
I2p |
SECONDARY VOLTAGE
U20 |
WEIGHT |
DIMENSIONS
w x h xd |
SECONDARY SIDE TRANSFORMER
IMPEDANCE
Z = R + jXL
(400 V version) |
| |
[ kVA ] |
[ kA ] |
[ V ] |
[ kg ] |
[ mm ] |
[ µW ]
|
| C - 18,5 - 100 - U1 - PG42 |
100 |
3.9 |
12.5 / 18.5 |
140 |
ca. 230 x 302 x 555 |
145 = 117 + j 85 |
| C - 22,3 - 200 - U1 - PG42 |
200 |
6.4 |
15.3 / 22.3 |
179 |
ca. 230 x 302 x 640 |
151 = 125 + j 84 |
SPLIT-CORE TYPE TRANSFORMERS
Connection Layout: H
|
Connection Layout: J
|
 |
 |
- Temperature monitoring
- Measuring coil (for CCR)
- Secondary circuit minitoring standard
|
| TYPE |
NOMINAL OUTPUT
S50
(at 50% ED) |
SECONDARY CONTINUOUS CURRENT
I2p |
SECONDARY VOLTAGE
U20 |
WEIGHT |
DIMENSIONS
w x h xd |
SECONDARY SIDE TRANSFORMER
IMPEDANCE
Z = R + jXL
(400 V version) |
| |
[ kVA ] |
[ kA ] |
[ V ] |
[ kg ] |
[ mm ] |
[ µW ]
|
| F2 - 12,5 - 200 - U1 - TMS |
200 |
11.3 |
9.0 / 10.0
11.2 / 12.5 |
214 |
ca. 250 x 360 x 620 |
55 = 38 + j 39 |
| F2 - 20,0 - 315 - U1 - TMS |
315 |
11.1 |
14.0 / 15.7
17.6 / 20.0 |
320 |
ca. 250 x 360 x 800 |
59 = 41 + j 42 |
| G2 - 16,0 - 500 - U1 - TMS |
500 |
22.5 |
8.0 / 10.0
12.5 / 16.0 |
370 |
ca. 280 x 400 x 810 |
26 = 20 + j 16 |
TRANSFORMERS WITH FLANGE CONNECTION
Connection Layout: F
|
Connection Layout: G
|
 |
 |
- Temperature monitoring
- Measuring coil (for CCR)
- Secondary circuit monitoring standard
|
| TYPE |
NOMINAL OUTPUT
S50
(at 50% ED) |
SECONDARY CONTINUOUS CURRENT
I2p |
SECONDARY VOLTAGE
U20 |
WEIGHT |
DIMENSIONS
w x h xd |
SECONDARY SIDE TRANSFORMER
IMPEDANCE
Z = R + jXL
(400 V version) |
| |
[ kVA ] |
[ kA ] |
[ V ] |
[ kg ] |
[ mm ] |
[ µW ]
|
| F2 - 12,5 - 200 - U1 - TMS |
200 |
11.3 |
9.0 / 10.0
11.2 / 12.5 |
214 |
ca. 250 x 360 x 620 |
55 = 38 + j 39 |
| F2 - 20,0 - 315 - U1 - TMS |
315 |
11.1 |
14.0 / 15.7
17.6 / 20.0 |
320 |
ca. 250 x 360 x 800 |
59 = 41 + j 42 |
| G2 - 16,0 - 500 - U1 - TMS |
500 |
22.5 |
8.0 / 10.0
12.5 / 16.0 |
370 |
ca. 280 x 400 x 810 |
26 = 20 + j 16 |
|