TRANSFORMERS

OPEL STANDARD

In accordance with DIN ISO 10656, and Opel standards, the transformer types (with varying primary voltages U1)listed below are currently in use:

INTEGRATED TRANSFORMERS


Connection Layout: B2

Connection Layout: B

  • Temperature monitoring
  • Measuring coil (for CCR)
  • Secondary circuit monitoring standard

TYPE NOMINAL OUTPUT
S50
(at 50% ED)
SECONDARY CONTINUOUS CURRENT
I2p
SECONDARY VOLTAGE
U20
WEIGHT DIMENSIONS
w x h xd
SECONDARY SIDE TRANSFORMER IMPEDANCE
Z = R + jXL
(400 V version)
  [ kVA ] [ kA ] [ V ] [ kg ] [ mm ] [ µW ]
B/2 - 4 - 10,0 - 50 - U1 - TMS 50 3.5 7.1 / 8.0
9.0 / 10.0
73 ca. 92 x 235 x 710  130 = 120 + j 51
B6-(1...5)-10,0-100-U1-TMS 100 7.1 7.1 / 8.0
9.0 / 10.0
115 ca. 184 x 235 x 560 67 = 51 + j 44 


SUSPENDED TRANSFORMERS


Connection Layout: C

 
 

TYPE NOMINAL OUTPUT
S50
(at 50% ED)
SECONDARY CONTINUOUS CURRENT
I2p
SECONDARY VOLTAGE
U20
WEIGHT DIMENSIONS
w x h xd
SECONDARY SIDE TRANSFORMER IMPEDANCE
Z = R + jXL
(400 V version)
  [ kVA ] [ kA ] [ V ] [ kg ] [ mm ] [ µW ]
C - 18,5 - 100 - U1 - PG42 100 3.9 12.5 / 18.5 140 ca. 230 x 302 x 555 145 = 117 + j 85 
C - 22,3 - 200 - U1 - PG42 200 6.4 15.3 / 22.3 179 ca. 230 x 302 x 640  151 = 125 + j 84


SPLIT-CORE TYPE TRANSFORMERS


Connection Layout: H

Connection Layout: J

  • Temperature monitoring
  • Measuring coil (for CCR)
  • Secondary circuit minitoring standard

TYPE NOMINAL OUTPUT
S50
(at 50% ED)
SECONDARY CONTINUOUS CURRENT
I2p
SECONDARY VOLTAGE
U20
WEIGHT DIMENSIONS
w x h xd
SECONDARY SIDE TRANSFORMER IMPEDANCE
Z = R + jXL
(400 V version)
  [ kVA ] [ kA ] [ V ] [ kg ] [ mm ] [ µW ]
F2 - 12,5 - 200 - U1 - TMS 200 11.3 9.0 / 10.0
11.2 / 12.5
214 ca. 250 x 360 x 620  55 = 38 + j 39
F2 - 20,0 - 315 - U1 - TMS 315 11.1 14.0 / 15.7
17.6 / 20.0
320 ca. 250 x 360 x 800  59 = 41 + j 42
G2 - 16,0 - 500 - U1 - TMS 500 22.5 8.0 / 10.0
12.5 / 16.0
370 ca. 280 x 400 x 810 26 = 20 + j 16


TRANSFORMERS WITH FLANGE CONNECTION


Connection Layout: F

Connection Layout: G

  • Temperature monitoring
  • Measuring coil (for CCR)
  • Secondary circuit monitoring standard

TYPE NOMINAL OUTPUT
S50
(at 50% ED)
SECONDARY CONTINUOUS CURRENT
I2p
SECONDARY VOLTAGE
U20
WEIGHT DIMENSIONS
w x h xd
SECONDARY SIDE TRANSFORMER IMPEDANCE
Z = R + jXL
(400 V version)
  [ kVA ] [ kA ] [ V ] [ kg ] [ mm ] [ µW ]
F2 - 12,5 - 200 - U1 - TMS 200 11.3 9.0 / 10.0
11.2 / 12.5
214 ca. 250 x 360 x 620  55 = 38 + j 39
F2 - 20,0 - 315 - U1 - TMS 315 11.1 14.0 / 15.7
17.6 / 20.0
320 ca. 250 x 360 x 800  59 = 41 + j 42
G2 - 16,0 - 500 - U1 - TMS 500 22.5 8.0 / 10.0
12.5 / 16.0
370 ca. 280 x 400 x 810 26 = 20 + j 16