Application
|
Integrated in standard machines for spot,
projection and roll seam welding
|
| Characteristics |
Compact, fully-cast design.
Especially suitable for connection of lamellar bands or permanent
rails |
| Standards |
DIN 44766, EXPERT Standard |
Various Connection types (click for more information):
| Connection
Layout: E |
 |
| Output Range: |
100 - 200 kVA |
| Secondary
Voltages: |
12.5 - 25.0V (single and multi-stage versions) |
| Other Features
(depending upon standard): |
- Temperature monitoring
- Measuring coil (for CCR)
|
NOMINAL OUTPUT
S50
(at 50% ED) |
SECONDARY CONTINUOUS CURRENT
I2p |
SECONDARY VOLTAGE
U20 |
WEIGHT |
DIMENSIONS
w x h xd |
SECONDARY SIDE TRANSFORMER
IMPEDANCE
Z = R + jXL
(400 V version) |
| [ kVA ] |
[ kA ] |
[ V ] |
[ kg ] |
[ mm ] |
[ µW ]
|
| 25 |
4.9 |
2.5 / 2.8
3.2 / 3.6 |
56 |
ca. 184 x 235 x 350 |
46 = 32 + j 33 |
| 40 |
5.6 |
3.6 / 4.0
4.5 / 5.0 |
70 |
ca. 184 x 235 x 400 |
49 = 37 + j 32 |
| 63 |
6.3 |
5.0 / 5.6
6.3 / 7.1 |
87 |
ca. 184 x 235 x 450 |
58 = 44 + j 38 |
| 100 |
7.1 |
7.1 / 8.0
9.0 / 10.0 |
113 |
ca. 184 x 235 x 560 |
68 = 52 + j 44 |
| 125 |
8.4 |
7.3 / 8.1
9.0 / 10.5 |
125 |
ca. 184 x 235 x 604 |
59 = 46 + j 37 |
[back to top]
| Connection
Layout: F |
 |
| Output Range: |
125 - 315 kVA |
| Secondary
Voltages: |
5.6 - 20.0V (multi-stage versions) |
| |
- Two water-cooled secondary circuits (parallel or series
connection)
- Temperature monitoring
|
| Other Features
(depending upon standard): |
- Measuring coil (for CCR)
- Secondary circuit monitoring
|
NOMINAL OUTPUT
S50
(at 50% ED) |
SECONDARY CONTINUOUS CURRENT
I2p |
SECONDARY VOLTAGE
U20 |
WEIGHT |
DIMENSIONS
w x h xd |
SECONDARY SIDE TRANSFORMER
IMPEDANCE
Z = R + jXL
(400 V version) |
| [ kVA ] |
[ kA ] |
[ V ] |
[ kg ] |
[ mm ] |
[ µW ]
|
| 125 |
11.1 |
5.6 / 6.3
7.1 / 8.0 |
165 |
ca. 250 x 360 x 500 |
38 = 31 + j 22 |
| 160 |
11.3 |
7.1 / 8.0
9.0 / 10.0 |
185 |
ca. 250 x 360 x 560 |
49 = 32 + j 37 |
| 200 |
11.3 |
9.0 / 10.0
11.2 / 12.5 |
226 |
ca. 250 x 360 x 620 |
56 = 39 + j 40 |
| 250 |
11.1 |
11.2 / 12.5
14.0 / 16.0 |
258 |
ca. 250 x 360 x 700 |
47 = 40 + j 25 |
| 315 |
11.1 |
14.0 / 15.7
17.6 / 20.0 |
320 |
ca. 250 x 360 x 800 |
63 = 44 + j 45 |
[back to top]
| Connection
Layout: G |
 |
| Output Range: |
200 - 530 kVA |
| Secondary
Voltages: |
5.0 - 18.3V (multi-stage versions) |
| |
- Two water-cooled secondary circuits (parallel or series
connection)
- Temperature monitoring standard
|
| Other Features
(depending upon standard): |
- Temperature monitoring
- Measuring coil (for CCR)
- Secondary circuit monitoring
|
NOMINAL OUTPUT
S50
(at 50% ED) |
SECONDARY CONTINUOUS CURRENT
I2p |
SECONDARY VOLTAGE
U20 |
WEIGHT |
DIMENSIONS
w x h xd |
SECONDARY SIDE TRANSFORMER
IMPEDANCE
Z = R + jXL
(400 V version) |
| [ kVA ] |
[ kA ] |
[ V ] |
[ kg ] |
[ mm ] |
[ µW ]
|
| 200 |
11.3 |
9.0 / 10.0
11.2 / 12.5 |
220 |
ca. 250 x 360 x 590 |
39 = 31 + j 24 |
| 250 |
11.2 |
11.2 / 12.5
14.0 / 16.0 |
272 |
ca. 250 x 360 x 680 |
51 = 41 + j 30 |
| 315 |
22.3 |
5.0 / 6.3
8.0 / 10.0 |
280 |
ca. 280 x 400 x 560 |
17 = 14 + j 10 |
| 340 |
17.9 |
9.5 / 13.4 |
260 |
ca. 250 x 360 x 630 |
37 = 25 + j 27 |
| 500 |
22.3 |
8.0 / 10.0
12.5 / 16.0 |
360 |
ca. 280 x 400 x 710 |
21 = 18 + j 11 |
| 530 |
22.5 |
8.3 / 10.5
13.3 / 16.6 |
371 |
ca. 280 x 400 x 810 |
24 = 19 + j 15 |
[back to top]
| Connection
Layout: 9 |
 |
| Output Range: |
25 - 125 kVA |
| Secondary
Voltages: |
2.5 - 10.5 V (multi-stage versions) |
| |
- One water-cooled secondary circuit
- Temperature monitoring standard
- Tap changer optional
|
NOMINAL OUTPUT
S50
(at 50% ED) |
SECONDARY CONTINUOUS CURRENT
I2p |
SECONDARY VOLTAGE
U20 |
WEIGHT |
DIMENSIONS
w x h xd |
SECONDARY SIDE TRANSFORMER
IMPEDANCE
Z = R + jXL
(400 V version) |
| [ kVA ] |
[ kA ] |
[ V ] |
[ kg ] |
[ mm ] |
[ µW ]
|
| 25 |
4.9 |
2.5 / 2.8
3.2 / 3.6 |
55 |
ca. 184 x 235 x 340 |
58 = 35 + j 46 |
| 40 |
5.6 |
3.6 / 4.0
4.5 / 5.0 |
70 |
ca. 184 x 235 x 390 |
54 = 38 + j 38 |
| 63 |
6.3 |
5.0 / 5.6
6.3 / 7.1 |
84 |
ca. 184 x 235 x 440 |
65 = 47 + j 45 |
| 100 |
7.1 |
7.1 / 8.0
9.0 / 10.0 |
113 |
ca. 184 x 235 x 550 |
71 = 53 + j 47 |
| 125 |
8.4 |
7.3 / 8.1
9.0 / 10.5 |
135 |
ca. 184 x 235 x 594 |
67 = 52 + j 42 |
[back to top]
| Connection
Layout: 10 |
 |
| Output Range: |
160 - 315 kVA |
| Secondary
Voltages: |
2.5 - 10.5 V (multi-stage versions) |
| |
- One water-cooled secondary circuit
- Temperature monitoring standard
|
NOMINAL OUTPUT
S50
(at 50% ED) |
SECONDARY CONTINUOUS CURRENT
I2p |
SECONDARY VOLTAGE
U20 |
WEIGHT |
DIMENSIONS
w x h xd |
SECONDARY SIDE TRANSFORMER
IMPEDANCE
Z = R + jXL
(400 V version) |
| [ kVA ] |
[ kA ] |
[ V ] |
[ kg ] |
[ mm ] |
[ µW ]
|
| 160 |
12.2 |
6.5 / 7.5
8.5 / 9.3 |
205 |
ca. 312 x 337 x 453 |
23 = 18 + j 13 |
| 200 |
13.5 |
7.5 / 8.5
9.3 / 10.5 |
223 |
ca. 312 x 337 x 483 |
27 = 24 + j 12 |
| 250 |
14.8 |
8.4 / 9.3
10.6 / 11.9 |
252 |
ca. 312 x 337 x 513 |
24 = 20 + j 13 |
| 315 |
17.0 |
9.3 / 10.5
11.9 / 13.1 |
271 |
ca. 312 x 337 x 543 |
29 = 25 + j 15 |
[back to top]
| Connection
Layout: 11 |
 |
| Output Range: |
315 - 600 kVA |
| Secondary
Voltages: |
5.0 - 15.8 V (multi-stage versions) |
| |
- One water-cooled secondary circuit
- Temperature monitoring standard
|
NOMINAL OUTPUT
S50
(at 50% ED) |
SECONDARY CONTINUOUS CURRENT
I2p |
SECONDARY VOLTAGE
U20 |
WEIGHT |
DIMENSIONS
w x h xd |
SECONDARY SIDE TRANSFORMER
IMPEDANCE
Z = R + jXL
(400 V version) |
| [ kVA ] |
[ kA ] |
[ V ] |
[ kg ] |
[ mm ] |
[ µW ]
|
| 315 |
22.3 |
5.0 / 6.7
8.5 / 10.0 |
280 |
ca. 280 x 400 x 650 |
|
| 400 |
20.6 |
6.8 / 8.7
10.8 / 13.6 |
310 |
ca. 280 x 400 x 650 |
20 = 16 + j 12 |
| 500 |
24.0 |
7.3 / 9.3
11.5 / 14.6 |
330 |
ca. 280 x 400 x 680 |
|
| 600 |
26.9 |
6.8 / 10.0
12.7 / 15.8 |
360 |
ca. 280 x 400 x 705 |
25 = 20 + j 15 |
[back to top]
|