TRANSFORMERS

INTEGRATED TRANSFORMERS

Application
Integration in multi-point tools
Characteristics Compact, fully-cast design
Especially suitable for connection of flexible cable
Standards DIN 44766, ISO 5826, ISO 7284, ISO 12166, NFA 82041, AUDI-VW 39-V5711, FORD UWT 001, Mercedes Benz 15.19.030, VOLVO VOV 8064.822-VC9H71002, u.a.

Connection Layout: A
Output Range: 25 - 160 kVA
Secondary Voltages: 3.6 - 12.5 V (single and multi-stage versions)
  Two water-cooled secondary circuits (parallel or series connection)
Other Features (depending upon standard):
  • Tap Charger with/without coupler socket
  • Coupler socket
  • Temperature monitoring
  • Measuring coil (for CCR)
  • Secondary circuit monitoring

NOMINAL OUTPUT
S50
(at 50% ED)
SECONDARY CONTINUOUS CURRENT
I2p
SECONDARY VOLTAGE
U20
WEIGHT DIMENSIONS
w x h xd
SECONDARY SIDE TRANSFORMER IMPEDANCE
Z = R + jXL
(400 V version)
[ kVA ] [ kA ] [ V ] [ kg ] [ mm ] [ µW ]
25 4.9 2.5 / 2.8
3.2 / 3.6
53 ca. 184 x 235 x 350 47 = 33 + j 33
40 5.6 3.6 / 4.0
4.5 / 5.0
68 ca. 184 x 235 x 400 49 = 38 + j 31
63 6.3 5.0 / 5.6
6.3 / 7.1
84 ca. 184 x 235 x 450 61 = 49 + j36
85 8.5 7.1 83 ca. 184 x 235 x 460 44 = 36 + j 25
100 7.1 7.1 / 8.0
9.0 / 10.0
113 ca. 184 x 235 x 560 68 = 52 + j 44
125 8.4 7.3 / 8.1
9.0 / 10.5
125 ca. 184 x 235 x 610 60 = 46 + j 39
160 9.0 12.5 119 ca. 184 x 235 x 615 61 = 48 + j 37


Connection Layout: B
Output Range: 25 - 180 kVA
Secondary Voltages: 2.5 - 12.6V (single and multi-stage versions)
  Two water-cooled secondary circuits (parallel or series connection)
Other Features (depending upon standard):
  • Tap Charger with/without coupler socket
  • Temperature monitoring
  • Measuring coil (for CCR)
  • Secondary circuit monitoring

NOMINAL OUTPUT
S50
(at 50% ED)
SECONDARY CONTINUOUS CURRENT
I2p
SECONDARY VOLTAGE
U20
WEIGHT DIMENSIONS
w x h xd
SECONDARY SIDE TRANSFORMER IMPEDANCE
Z = R + jXL
(400 V version)
[ kVA ] [ kA ] [ V ] [ kg ] [ mm ] [ µW ]
25 4.9 2.5 / 2.8
3.2 / 3.6
53 ca. 184 x 235 x 350 46 = 32 + j 33
40 5.6 3.6 / 4.0
4.5 / 5.0
68 ca. 184 x 235 x 400 49 = 38 + j 31
63 6.3 5.0 / 5.6
6.3 / 7.1
84 ca. 184 x 235 x 450 61 = 49 + j 36
100 7.1 7.1 / 8.0
9.0 / 10.0
113 ca. 184 x 235 x 560 68 = 52 + j 44
125 8.4 7.3 / 8.1
9.0 / 10.5
125 ca. 184 x 235 x 610 67 = 53 + j 41
150 9.1 7.9 / 8.8
10.0 / 11.6
150 ca. 197 x 260 x 621 69 = 48 + j 50
180 10.0 9.0 / 10.0
11.2 / 12.6
147 ca. 184 x 235 x 590 64 = 50 + j 40


Connection Layout: B2
Output Range: 32 - 63 kVA
Secondary Voltages: 5.0 - 10.0V (single and multi-stage versions)
  One water-cooled secondary circuit
Other Features (depending upon standard):
  • Temperature monitoring
  • Measuring coil (for CCR)
  • Secondary circuit monitoring

NOMINAL OUTPUT
S50
(at 50% ED)
SECONDARY CONTINUOUS CURRENT
I2p
SECONDARY VOLTAGE
U20
WEIGHT DIMENSIONS
w x h xd
SECONDARY SIDE TRANSFORMER IMPEDANCE
Z = R + jXL
(400 V version)
[ kVA ] [ kA ] [ V ] [ kg ] [ mm ] [ µW ]
32 3.2 5.0 / 5.6
6.3 / 7.1
56 ca. 92 x 235 x 595 104 = 96 + j 40
40 4.0 7.1 54 ca. 92 x 235 x 595 96 = 85 + j 45
50 3.5 7.1 / 8.0
9.0 / 10.0
73 ca. 92 x 235 x 710 133 = 121 + j 55
63 4.5 10.0 72 ca. 92 x 235 x 710 104 = 91 + j 50