TRANSFORMERS

DAIMLER-CHRYSLER STANDARD

In accordance with DIN ISO 10656, Mercedes Benz standards 15.19.030, 15.01.042, 15.19.041, 15.19.042 and the project specification for the W168, W210 and W220, the transformer types (with varying primary voltages U1) listed below are currently in use:

INTEGRATED TRANSFORMERS


Connection Layout: A

 
  • Coupler socket and tap changer standard
  • Measuring coil (for CCR)
  • Secondary circuit monitoring standard

TYPE NOMINAL OUTPUT
S50
(at 50% ED)
SECONDARY CONTINUOUS CURRENT
I2p
SECONDARY VOLTAGE
U20
WEIGHT DIMENSIONS
w x h xd
SECONDARY SIDE TRANSFORMER IMPEDANCE
Z = R + jXL
(400 V version)
  [ kVA ] [ kA ] [ V ] [ kg ] [ mm ] [ µW ]
A6-1-7,1 - 40 - U1 - MS 40 4.0 5.0 / 5.6
6.4 / 7.1
81 ca. 184 x 235 x 450 71 = 57 + j 42
A6 - 1 - 10,0 - 63 - U1 - MS 63 4.5 7.1 / 8.0
9.0 / 10.0
113 ca. 184 x 235 x 545 86 = 70 + j 50
A6 - 1 - 10,0 - 100 - U1 - MS 100

7.0

7.1 / 8.0
9.0 / 10.0
115 ca. 184 x 235 x 500 69 = 55 + j 42


SUSPENDED TRANSFORMERS


Connection Layout: C

 
  • with / without suspension fittings

TYPE NOMINAL OUTPUT
S50
(at 50% ED)
SECONDARY CONTINUOUS CURRENT
I2p
SECONDARY VOLTAGE
U20
WEIGHT DIMENSIONS
w x h xd
SECONDARY SIDE TRANSFORMER IMPEDANCE
Z = R + jXL
(400 V version)
  [ kVA ] [ kA ] [ V ] [ kg ] [ mm ] [ µW ]
C - 17,9 - 115 - U1 - PG42 115 4.5 17.9 116 ca. 200 x 275 x 509 164 = 136 + j 92
C - 22,8 - 150 - U1 - PG42 150 4.6 22.8 132 ca. 200 x 275 x 544 200 = 176 + j 95


TRANSFORMERS WITH FLANGE CONNECTION


Connection Layout: G

 
  • Measuring coil (for CCR)
  • Secondary circuit monitoring standard

TYPE NOMINAL OUTPUT
S50
(at 50% ED)
SECONDARY CONTINUOUS CURRENT
I2p
SECONDARY VOLTAGE
U20
WEIGHT DIMENSIONS
w x h xd
SECONDARY SIDE TRANSFORMER IMPEDANCE
Z = R + jXL
(400 V version)
  [ kVA ] [ kA ] [ V ] [ kg ] [ mm ] [ µW ]
G2 - 12,5 - 200 - U1 - MS 200 11.3 9.0 / 10.0
11.2 / 12.5
220 ca. 250 x 330 x 590 39 = 31 + j 24
G2 - 16,0 - 250 - U1 - MS 250 11.2 11.2 / 12.5
14.0 / 16.0
272 ca. 250 x 330 x 680 51 = 41 + j 30


SPLIT-CORE TYPE TRANSFORMERS


Connection Layout: J

 
  • Temperature monitoring
  • Measuring coil (for CCR)
  • Secondary circuit minitoring
  • MC contact pins are standard

TYPE NOMINAL OUTPUT
S50
(at 50% ED)
SECONDARY CONTINUOUS CURRENT
I2p
SECONDARY VOLTAGE
U20
WEIGHT DIMENSIONS
w x h xd
SECONDARY SIDE TRANSFORMER IMPEDANCE
Z = R + jXL
(400 V version)
  [ kVA ] [ kA ] [ V ] [ kg ] [ mm ] [ µW ]
J-7,1-5,4-U1-TMS-MC135 54 5.4 7.1 29.5 ca. 125 x 160 x 292 138 = 121 + j 66
J-8,0-5,4-U1-TMS-MC135 61 5.4 8.0 32 ca. 125 x 160 x 309 147 = 138 + j 5 
J-10,0-5,4-U1-TMS-MC135
or
J-10,0-5,4-U1-TMS-MC180
76 5.4 10.0 38.5 ca. 125 x 160 x 360 166 = 150 + j 71
J-13,5-5,4-U1-TMS-MC180 103 5.4 13.5 51.5 ca. 125 x 160 x 460 208 = 187 + j 91