In accordance with DIN ISO 10656, Mercedes Benz standards 15.19.030,
15.01.042, 15.19.041, 15.19.042 and the project specification for
the W168, W210 and W220, the transformer types (with varying primary
voltages U1) listed below are currently in use:
INTEGRATED TRANSFORMERS
Connection Layout: A
|

|
 |
|
- Coupler socket and tap changer standard
- Measuring coil (for CCR)
- Secondary circuit monitoring standard
|
| TYPE |
NOMINAL OUTPUT
S50
(at 50% ED) |
SECONDARY CONTINUOUS CURRENT
I2p |
SECONDARY VOLTAGE
U20 |
WEIGHT |
DIMENSIONS
w x h xd |
SECONDARY SIDE TRANSFORMER
IMPEDANCE
Z = R + jXL
(400 V version) |
| |
[ kVA ] |
[ kA ] |
[ V ] |
[ kg ] |
[ mm ] |
[ µW
] |
| A6-1-7,1 - 40
- U1 - MS |
40 |
4.0 |
5.0 / 5.6
6.4 / 7.1 |
81 |
ca. 184 x 235 x 450 |
71 = 57 + j 42 |
| A6 - 1 - 10,0
- 63 - U1 - MS |
63 |
4.5 |
7.1 / 8.0
9.0 / 10.0 |
113 |
ca. 184 x 235 x 545 |
86 = 70 + j 50 |
| A6 - 1 - 10,0
- 100 - U1 - MS |
100 |
7.0
|
7.1 / 8.0
9.0 / 10.0 |
115 |
ca. 184 x 235 x 500 |
69 = 55 + j 42 |
SUSPENDED TRANSFORMERS
Connection Layout: C
|

|
 |
|
- with / without suspension fittings
|
| TYPE |
NOMINAL OUTPUT
S50
(at 50% ED) |
SECONDARY CONTINUOUS CURRENT
I2p |
SECONDARY VOLTAGE
U20 |
WEIGHT |
DIMENSIONS
w x h xd |
SECONDARY SIDE TRANSFORMER
IMPEDANCE
Z = R + jXL
(400 V version) |
| |
[ kVA ] |
[ kA ] |
[ V ] |
[ kg ] |
[ mm ] |
[ µW ]
|
| C - 17,9 - 115 - U1 - PG42 |
115 |
4.5 |
17.9 |
116 |
ca. 200 x 275 x 509 |
164 = 136 + j 92 |
| C - 22,8 - 150 - U1 - PG42 |
150 |
4.6 |
22.8 |
132 |
ca. 200 x 275 x 544 |
200 = 176 + j 95 |
TRANSFORMERS WITH FLANGE CONNECTION
Connection Layout: G
|

|
 |
|
- Measuring coil (for CCR)
- Secondary circuit monitoring standard
|
| TYPE |
NOMINAL OUTPUT
S50
(at 50% ED) |
SECONDARY CONTINUOUS CURRENT
I2p |
SECONDARY VOLTAGE
U20 |
WEIGHT |
DIMENSIONS
w x h xd |
SECONDARY SIDE TRANSFORMER
IMPEDANCE
Z = R + jXL
(400 V version) |
| |
[ kVA ] |
[ kA ] |
[ V ] |
[ kg ] |
[ mm ] |
[ µW ]
|
| G2 - 12,5 - 200 - U1 - MS |
200 |
11.3 |
9.0 / 10.0
11.2 / 12.5 |
220 |
ca. 250 x 330 x 590 |
39 = 31 + j 24 |
| G2 - 16,0 - 250 - U1 - MS |
250 |
11.2 |
11.2 / 12.5
14.0 / 16.0 |
272 |
ca. 250 x 330 x 680 |
51 = 41 + j 30 |
SPLIT-CORE TYPE TRANSFORMERS
Connection Layout: J
|

|
 |
|
- Temperature monitoring
- Measuring coil (for CCR)
- Secondary circuit minitoring
- MC contact pins are standard
|
| TYPE |
NOMINAL OUTPUT
S50
(at 50% ED) |
SECONDARY CONTINUOUS CURRENT
I2p |
SECONDARY VOLTAGE
U20 |
WEIGHT |
DIMENSIONS
w x h xd |
SECONDARY SIDE TRANSFORMER
IMPEDANCE
Z = R + jXL
(400 V version) |
| |
[ kVA ] |
[ kA ] |
[ V ] |
[ kg ] |
[ mm ] |
[ µW ]
|
| J-7,1-5,4-U1-TMS-MC135 |
54 |
5.4 |
7.1 |
29.5 |
ca. 125 x 160 x 292 |
138 = 121 + j 66 |
| J-8,0-5,4-U1-TMS-MC135 |
61 |
5.4 |
8.0 |
32 |
ca. 125 x 160 x 309 |
147 = 138 + j 5 |
J-10,0-5,4-U1-TMS-MC135
or
J-10,0-5,4-U1-TMS-MC180 |
76 |
5.4 |
10.0 |
38.5 |
ca. 125 x 160 x 360 |
166 = 150 + j 71 |
| J-13,5-5,4-U1-TMS-MC180 |
103 |
5.4 |
13.5 |
51.5 |
ca. 125 x 160 x 460 |
208 = 187 + j 91 |
|